Vibration measurements and analyses at ANKA beamline IMAGE in October 2013. Report

Groos, Jörn; Ritter, Joachim R. R.

Abstract:
The KIT Geophysical Institute measured the ground motion velocity with six seismometers inside the IMAGE experimental hutch 2 at ANKA. Purpose is the quantitative assessment of the ground motions for the following design of a work-place table with active vibration insulation. The data set of 14 days is analyzed in the time and frequency domains. The ground motions are characterized in two frequency ranges: 1-90 Hz (mainly man-made vibrations) and 0.008-1 Hz (natural vibrations and ground tilt).

Open Access Logo


Volltext §
DOI: 10.5445/IR/1000037417
Zugehörige Institution(en) am KIT Geophysikalisches Institut (GPI)
Publikationstyp Forschungsbericht
Jahr 2013
Sprache Englisch
Identifikator ISSN: 2194-1629
urn:nbn:de:swb:90-374171
KITopen-ID: 1000037417
Verlag KIT, Karlsruhe
Umfang 27 S.
Serie KIT Scientific Working Papers ; 15
Schlagworte seismic noise; ground motions; synchrotron light source; ANKA; vibration insulation