KIT | KIT-Bibliothek | Impressum

Expansion of the Severe Accident Code MELCOR by Coupling External Models (KIT Scientific Reports ; 7726)

Dietrich, Philipp



Abstract (englisch): In this work the MELCOR-Code is coupled with the Phase-Change Effective Convectivity Model (PECM) using the developed universal coupling tool DINAMO to improve the prediction of molten core material in the lower head during a severe accident in a Nuclear Power Plan. The coupled system was tested by simulating different experiments performed in the LIVE-facility. The coupled simulation of an entire severe accident shows the necessity for more detailed models in integral codes.


Zugehörige Institution(en) am KIT Institut für Kern- und Energietechnik (IKET)
Publikationstyp Hochschulschrift
Jahr 2016
Sprache Englisch
Identifikator DOI: 10.5445/KSP/1000061998
ISBN: 978-3-7315-0603-4
URN: urn:nbn:de:0072-619982
KITopen ID: 1000061998
Reportnummer: KIT-SR 7726
HGF-Programm 32.02.11; LK 01
Verlag KIT Scientific Publishing, Karlsruhe
Umfang XII, 135 S.
Abschlussart Dissertation
Fakultät Fakultät für Maschinenbau (MACH)
Institut Institut für Kern- und Energietechnik (IKET)
Prüfungsdaten 27.06.2016
Referent/Betreuer Prof. A. Class
Schlagworte MELCOR, PECM, LIVE, Kopplung, In-Vessel Melt Retention MELCOR, PECM, LIVE, Coupling, In-Vessel Melt Retention
Bestellung Die Veröffentlichung ist bei KIT Scientific Publishing erschienen.
Weitere Informationen sowie gegebenenfalls Bestellmöglichkeiten finden Sie hier.
KIT – Die Forschungsuniversität in der Helmholtz-Gemeinschaft KITopen Landing Page