The physical design of cavity and magnetron injection gun (MIG) for a realistic, DEMO-compatible, coaxial-cavity 238 GHz 2 MW CW fusion gyrotron is developed in this work, having auxiliary frequencies at 170 GHz and 204 GHz. Novel systematic approaches towards multi-frequency mode selection, magnet requirements, and MIG design are presented. Mode deterioration and voltage depression variation due to insert misalignment versus cavity wall and/or versus electron beam are studied.


Zugehörige Institution(en) am KIT Institut für Hochleistungsimpuls- und Mikrowellentechnik (IHM)
Publikationstyp Hochschulschrift
Jahr 2017
Sprache Englisch
Identifikator DOI: 10.5445/KSP/1000068000
ISBN: 978-3-7315-0652-2
ISSN: 2192-2764
URN: urn:nbn:de:0072-680008
KITopen ID: 1000068000
HGF-Programm 31.03.02; LK 01
Verlag KIT Scientific Publishing, Karlsruhe
Umfang XX, 236 S.
Serie Karlsruher Forschungsberichte aus dem Institut für Hochleistungsimpuls- und Mikrowellentechnik ; 11
Abschlussart Dissertation
Fakultät Fakultät für Elektrotechnik und Informationstechnik (ETIT)
Institut Institut für Hochleistungsimpuls- und Mikrowellentechnik (IHM)
Prüfungsdatum 21.02.2017
Referent/Betreuer Prof. J. Jelonnek
Lizenz CC BY-SA 4.0: Creative Commons Namensnennung – Weitergabe unter gleichen Bedingungen 4.0 International
Schlagworte Gyrotron; koaxialer Innenleiter; Versatz; Mehrfrequenz-Gyrotron; Kernfusion gyrotron; coaxial insert; misalignment; multifrequency gyrotron; nuclear fusion
Bestellung Die Veröffentlichung ist bei KIT Scientific Publishing erschienen.
Weitere Informationen sowie gegebenenfalls Bestellmöglichkeiten finden Sie hier.
KIT – Die Forschungsuniversität in der Helmholtz-Gemeinschaft KITopen Landing Page