KIT | KIT-Bibliothek | Impressum | Datenschutz

Use of Thermography and Ultrasound for the Quality Control of SMC Lightweight Material Reinforced by Carbon Fiber Tapes

Zaiß, M. 1; Jank, Merle-Hendrikje; Netzelmann, Udo; Waschkies, T.; Rabe, Ute; Herrmann, Hans-Georg; Thompson, Michael; Lanza, G. 1
1 Institut für Produktionstechnik (WBK), Karlsruher Institut für Technologie (KIT)

Abstract:

Growing requirements of Sheet Molding Compound (SMC) parts make new material combinations necessary. One strategy is to reinforce SMC with unidirectional carbon fiber tapes to improve its mechanical properties. As quality assessment of cured parts is necessary, examination of semi-finished materials would be favorable. Two types of nondestructive testing methods, Thermography and Ultrasound, are compared to determine the best control method. These methods are examined on cured plates and semi-finished material to identify defects like air inclusions, delamination, misaligned fibers and microstructural changes. The focus of this paper is an assessment of the testing methods for the manufacturing process.


Verlagsausgabe §
DOI: 10.5445/IR/1000071408
Veröffentlicht am 13.05.2022
Originalveröffentlichung
DOI: 10.1016/j.procir.2016.06.039
Scopus
Zitationen: 13
Dimensions
Zitationen: 18
Cover der Publikation
Zugehörige Institution(en) am KIT Institut für Produktionstechnik (WBK)
Publikationstyp Zeitschriftenaufsatz
Publikationsjahr 2017
Sprache Englisch
Identifikator ISSN: 2212-8271
KITopen-ID: 1000071408
Erschienen in Procedia CIRP
Verlag Elsevier
Band 62
Seiten 33 – 38
Bemerkung zur Veröffentlichung 10th CIRP Conference on Intelligent Computation in Manufacturing Engineering (CIRP ICME '16), 20 - 22 July 2016, Ischia, Italy
Vorab online veröffentlicht am 18.05.2017