KIT | KIT-Bibliothek | Impressum | Datenschutz

Heat transfer and pressure drop in the main heat exchanger of a cryogenic mixed refrigerant cycle

Gomse, D. 1; Grohmann, S. ORCID iD icon 1
1 Institut für Technische Thermodynamik und Kältetechnik (TTK), Karlsruher Institut für Technologie (KIT)

Abstract (englisch):

Mixed refrigerant cycles (MRCs) offer a cost- and energy-efficient cooling method for the temperature range between 80 and 200 K. The performance of MRCs is substantially influenced by entropy production in the main heat exchanger. Due to the wide-boiling refrigerant mixtures applied in MRCs, a reliable design of the heat exchangers is challenging as two-phase heat transfer and pressure drop in both fluid streams must be considered simultaneously.
This contribution presents a literature review on the boiling/condensation heat transfer and pressure drop of zeotropic mixtures at low temperatures. Based on this survey, suitable correlations for the design of MRC heat exchangers are identified.


Verlagsausgabe §
DOI: 10.5445/IR/1000093953
Veröffentlicht am 06.05.2019
Originalveröffentlichung
DOI: 10.1088/1757-899X/502/1/012027
Scopus
Zitationen: 2
Dimensions
Zitationen: 4
Cover der Publikation
Zugehörige Institution(en) am KIT Institut für Technische Physik (ITEP)
Institut für Technische Thermodynamik und Kältetechnik (TTK)
Publikationstyp Zeitschriftenaufsatz
Publikationsjahr 2019
Sprache Englisch
Identifikator ISSN: 1757-899X
KITopen-ID: 1000093953
HGF-Programm 37.06.02 (POF III, LK 01) New Power Network Technology
Erschienen in IOP conference series / Materials science and engineering
Verlag Institute of Physics Publishing Ltd (IOP Publishing Ltd)
Band 502
Heft 1
Seiten 012027
Vorab online veröffentlicht am 15.04.2019
Nachgewiesen in Scopus
Dimensions
Globale Ziele für nachhaltige Entwicklung Ziel 7 – Bezahlbare und saubere Energie
KIT – Die Forschungsuniversität in der Helmholtz-Gemeinschaft
KITopen Landing Page