KIT | KIT-Bibliothek | Impressum | Datenschutz

Testing of a 120kV-Pulse Generator with Droop Compensation

Sack, Martin 1; Hochberg, Martin 1; Herzog, Dennis 1; Fetzer, Renate 1; An, Wladimir 1; Weisenburger, Alfons 1; Müller, Georg 1
1 Karlsruher Institut für Technologie (KIT)

Abstract (englisch):

A 149-stage Marx-type pulse generator is currently being tested. The generator delivers substantially rectangular pulses with a voltage amplitude of up to 120 kV at a rise time of approximately 100 ns into a resistive load. The generator has been designed for a peak current of 600 A. In order to generate rectangular pulses up to a pulse length of 100 µs with a moderate stage capacitance the droop of the output voltage can be compensated by subsequently activating additional stages.


Originalveröffentlichung
DOI: 10.23919/EPE.2019.8915104
Scopus
Zitationen: 1
Dimensions
Zitationen: 1
Zugehörige Institution(en) am KIT Institut für Hochleistungsimpuls- und Mikrowellentechnik (IHM)
Publikationstyp Proceedingsbeitrag
Publikationsmonat/-jahr 09.2019
Sprache Englisch
Identifikator ISBN: 978-90-75815-31-3
KITopen-ID: 1000104198
HGF-Programm 32.01.13 (POF III, LK 01) Transmutation: Flüssigmetalltechnologie
Erschienen in 2019 21st European Conference on Power Electronics and Applications (EPE '19 ECCE Europe)
Veranstaltung 21st European Conference on Power Electronics and Applications (EPE`23 ECCE Europe 2019), Genova, Italien, 02.09.2019 – 06.09.2019
Verlag Institute of Electrical and Electronics Engineers (IEEE)
Seiten P.1–P.8
Nachgewiesen in Dimensions
Scopus
KIT – Die Forschungsuniversität in der Helmholtz-Gemeinschaft
KITopen Landing Page