KIT | KIT-Bibliothek | Impressum | Datenschutz

In vivo monitoring of corneal dendritic cells in the subbasal nerve plexus during Trastuzumab and Paclitaxel breast cancer therapy - a one-year follow-up

Bohn, Sebastian; Stache, Nadine; Sperlich, Karsten; Allgeier, Stephan ORCID iD icon 1; Köhler, Bernd 1; Bartschat, Andreas 1; Do, Ha-Vy; George, Christian; Guthoff, Rudolf F.; Stachs, Angrit; Stachs, Oliver; Sterenczak, Katharina Anna
1 Institut für Automation und angewandte Informatik (IAI), Karlsruher Institut für Technologie (KIT)

Abstract (englisch):

Paclitaxel and trastuzumab have been associated with adverse effects including chemotherapy-induced peripheral neuropathy (CIPN) or ocular complications. In vivo confocal laser scanning microscopy (CLSM) of the cornea could be suitable for assessing side effects since the cornea is susceptible to, i.e., neurotoxic stimuli. The study represents a one-year follow-up of a breast cancer patient including large-area in vivo CLSM of the subbasal nerve plexus (SNP), nerve function testing, and questionnaires during paclitaxel and trastuzumab therapy. Six monitoring sessions (one baseline, four during, and one after therapy) over 58 weeks were carried out. Large-area mosaics of the SNP were generated, and identical regions within all sessions were assigned. While corneal nerve morphology did not cause alterations, the number of dendritic cells (DCs) showed dynamic changes with a local burst at 11 weeks after baseline. Simultaneously, paclitaxel treatment was terminated due to side effects, which, together with DCs, returned to normal levels as the therapy progressed. Longitudinal in vivo CLSM of the SNP could complement routine examinations and be helpful to generate a comprehensive clinical picture. ... mehr


Verlagsausgabe §
DOI: 10.5445/IR/1000145998
Veröffentlicht am 11.05.2022
Originalveröffentlichung
DOI: 10.3390/diagnostics12051180
Scopus
Zitationen: 4
Dimensions
Zitationen: 4
Cover der Publikation
Zugehörige Institution(en) am KIT Institut für Automation und angewandte Informatik (IAI)
Publikationstyp Zeitschriftenaufsatz
Publikationsjahr 2022
Sprache Englisch
Identifikator ISSN: 2075-4418
KITopen-ID: 1000145998
HGF-Programm 43.31.02 (POF IV, LK 01) Devices and Applications
Weitere HGF-Programme 47.14.02 (POF IV, LK 01) Information Storage and Processing in the Cell Nucleus
Erschienen in Diagnostics
Verlag MDPI
Band 12
Heft 5
Seiten 1180
Projektinformation 3D-CCM (DFG, DFG EIN, MI 1315/5-2)
3D-CCM (DFG, DFG EIN, KO 5003/1-2)
Vorab online veröffentlicht am 09.05.2022
Nachgewiesen in Dimensions
Web of Science
Scopus
KIT – Die Forschungsuniversität in der Helmholtz-Gemeinschaft
KITopen Landing Page