KIT | KIT-Bibliothek | Impressum | Datenschutz

Conceptual Design of a Liquid Helium Vertical Test-Stand for 2m long Superconducting Undulator Coils

Marchetti, B.; Abeghyan, S.; Baader, J.; Barbanotti, S.; Casalbuoni, S.; Di Felice, M.; Eckoldt, H.-J.; Englisch, U.; Grattoni, V.; Grau, A. 1; Hauberg, A.; Jensch, K.; La Civita, D.; Lederer, S.; Lilje, L.; Ramalingam, R.; Schnautz, T.; Vannoni, M.; Yakopov, M.; ... mehr

Abstract:

Superconducting Undulators (SCUs) can produce higher photon flux and cover a wider photon energy range compared to permanent magnet undulators (PMUs) with the same vacuum gap and period length. To build the know-how to implement superconducting undulators for future upgrades of the European XFEL facility, the test stand SUNDAE1 for the characterization of SCU is being developed. The purpose of SUNDAE1 is the training, tuning and development of new SCU coils by means of precise magnetic field measurements. The experimental setup will allow the characterization of magnets up to 2m in length. These magnets will be immersed in a Helium bath at 4K or 2K temperature. In this article, we describe the experimental setup and highlight its expected performances.


Verlagsausgabe §
DOI: 10.5445/IR/1000155906
Veröffentlicht am 16.02.2023
Originalveröffentlichung
DOI: 10.1088/1742-6596/2380/1/012027
Scopus
Zitationen: 4
Dimensions
Zitationen: 4
Cover der Publikation
Zugehörige Institution(en) am KIT Institut für Beschleunigerphysik und Technologie (IBPT)
Publikationstyp Zeitschriftenaufsatz
Publikationsdatum 23.12.2022
Sprache Englisch
Identifikator ISSN: 1742-6588, 1742-6596
KITopen-ID: 1000155906
HGF-Programm 54.11.11 (POF IV, LK 01) Accelerator Operation, Research and Development
Erschienen in Journal of Physics: Conference Series
Verlag Institute of Physics Publishing Ltd (IOP Publishing Ltd)
Band 2380
Seiten Art.-Nr.: 012027
Nachgewiesen in Dimensions
Scopus