KIT | KIT-Bibliothek | Impressum | Datenschutz

Percival soft X-ray CMOS Imager for Photon Science – Status and Prospects

Hajheidari, M.; Wunderer, C. B.; Correa, J.; Marras, A.; Lange, S.; Dahlgruen, M.; Gebert, J.; Krivan, F.; Shevyakov, I.; Vardanyan, V.; Wendt, Th; Hoesch, M.; Bagschik, K.; Guerrini, N.; Marsh, B.; Sedgwick, I.; Nicholls, T.; Cautero, G.; Giuressi, D.; ... mehr

Abstract:

Percival is a CMOS-based imager with 2 megapixels, also called P2M, designed for photon science experiments. The first generation of the P2M sensor showed some performance issues. Specifically, ADCs in full-speed operation mode are affected by crosstalk and show a non-linear and uncorrectable response. A firmware hack to the readout and data acquisition system has been introduced to partially overcome these effects, at the cost of limiting the frame rate to 83 Hz. Moreover, a non-uniform dark response of the sensor pixels is observed, explained by non-uniform bias currents across the chip: two opposite edges of the sensor cannot be digitized when applying biases that have the centre of the sensor operating normally. These issues are addressed in the re-submission of the chip. In this contribution, we present the current status of the detector and the first results from the re-designed sensor.


Verlagsausgabe §
DOI: 10.5445/IR/1000184176
Veröffentlicht am 25.08.2025
Cover der Publikation
Zugehörige Institution(en) am KIT Institut für Prozessdatenverarbeitung und Elektronik (IPE)
Publikationstyp Zeitschriftenaufsatz
Publikationsdatum 01.05.2025
Sprache Englisch
Identifikator ISSN: 1742-6588, 1742-6596
KITopen-ID: 1000184176
HGF-Programm 54.12.01 (POF IV, LK 01) Detection and Measurement
Erschienen in Journal of Physics: Conference Series
Verlag Institute of Physics Publishing Ltd (IOP Publishing Ltd)
Band 3010
Heft 1
Seiten 012129
Nachgewiesen in Dimensions
OpenAlex
Scopus
KIT – Die Universität in der Helmholtz-Gemeinschaft
KITopen Landing Page