A new diagnostic system designed for monitoring low-Z plasma impurities was constructed and successfully commissioned during the operational phase OP2 of the Wendelstein 7-X experiment [1]. The system is working based on recording the emission of the Lyman-α spectral lines emitted by hydrogen-like ions of carbon and oxygen (a second subsystem designed to measure the boron and nitrogen line is planned to be installed in the future). The first results obtained during the campaign OP2 showed that the system works following the design assumptions, and its properties comply with the numerical simulations. These findings suggest that this diagnostic system can be an important tool for scientific research of the stellarator plasmas.


Zugehörige Institution(en) am KIT Institut für Hochleistungsimpuls- und Mikrowellentechnik (IHM)
Publikationstyp Zeitschriftenaufsatz
Publikationsmonat/-jahr 02.2026
Sprache Englisch
Identifikator ISSN: 0920-3796
KITopen-ID: 1000188248
HGF-Programm 31.13.02 (POF IV, LK 01) Plasma Heating & Current Drive Systems
Erschienen in Fusion Engineering and Design
Verlag Elsevier
Band 223
Seiten 115542
Projektinformation EUROfusion (EU, EURATOM, 101052200)
Schlagwörter Wendelstein 7-X, Stellarator plasma, Plasma diagnostic, Plasma impurities, XUV spectroscopy