KIT | KIT-Bibliothek | Impressum | Datenschutz

Evaluation of the reliability of Rayleigh scattering as calibration method for the Thomson scattering diagnostic at W7-X

W7-X Team 1; Wagner, J. ; Fuchert, G.; Brunner, K. J.; Pasch, E.; Knauer, J.; Bozhenkov, S. A.; Hirsch, M.; Wolf, R. C.
1 Institut für Hochleistungsimpuls- und Mikrowellentechnik (IHM), Karlsruher Institut für Technologie (KIT)

Abstract:

Rayleigh scattering is used in an in-situ approach to determine the relative and absolute calibration factors of the Thomson scattering diagnostic at Wendelstein 7-X (W7-X). Using light pulses from an optical parametric oscillator (OPO), it is shown for the first time that the method is allowing for the calibration of all spatial channels (scattering volumes) at once. That has been realized by reducing the high amount of stray light observed in prior attempts. The improved setup is presented and compared to the literature ones. The Rayleigh scattering evaluation is containing the vacuum stray light measurement, which is yielding a rough estimate of the relative calibration without the need of any gas and used for background subtraction and a Rayleigh measurement on argon inside the vessel. The pressure dependency of the Rayleigh contribution in argon is evaluated for two wavelengths in each spectral channel. At the pressure of 377 mbar, the full spectral measurement used for the calibration is recorded. Under the assumption of the typical Rayleigh scattering cross-section from literature, the relative and absolute calibration factors are estimated. ... mehr


Verlagsausgabe §
DOI: 10.5445/IR/1000190733
Veröffentlicht am 17.02.2026
Originalveröffentlichung
DOI: 10.1088/1748-0221/21/02/C02009
Cover der Publikation
Zugehörige Institution(en) am KIT Institut für Hochleistungsimpuls- und Mikrowellentechnik (IHM)
Publikationstyp Zeitschriftenaufsatz
Publikationsdatum 12.02.2026
Sprache Englisch
Identifikator ISSN: 1748-0221
KITopen-ID: 1000190733
HGF-Programm 31.13.02 (POF IV, LK 01) Plasma Heating & Current Drive Systems
Erschienen in Journal of Instrumentation
Verlag Institute of Physics Publishing Ltd (IOP Publishing Ltd)
Band 21
Heft 02
Seiten Article no: C02009
Projektinformation EUROfusion (EU, EURATOM, 101052200)
Bemerkung zur Veröffentlichung 21st International Symposium on Laser-Aided Plasma Diagnostics, Saillon, Switzerland, 1–5 September 2025
Schlagwörter Detector alignment and calibration methods (lasers, sources, particle-beams); Plasma, diagnostics - interferometry, spectroscopy and imaging; Data processing methods
Nachgewiesen in OpenAlex
KIT – Die Universität in der Helmholtz-Gemeinschaft
KITopen Landing Page