KIT | KIT-Bibliothek | Impressum | Datenschutz

Fluidic diode for critical two-phase flows

Dumond, Julien Xavier Pierre

Abstract:

A fluidic diode for critical two-phase flows is developed and validated for the boiling water reactor KERENA. To investigate the fluidic behavior of this fluidic diode, a 3D cavitation model accounting for non-equilibrium and quality effects is developed. This model is the first application of the stochastic-field method to multi-phase flow. Validation of this model indicates that agreement with experimental results is obtained for very differing applications with a fixed set of model constants.


Volltext §
DOI: 10.5445/IR/1000032396
Cover der Publikation
Zugehörige Institution(en) am KIT Institut für Kern- und Energietechnik (IKET)
Publikationstyp Hochschulschrift
Publikationsjahr 2012
Sprache Englisch
Identifikator urn:nbn:de:swb:90-323968
KITopen-ID: 1000032396
HGF-Programm 32.21.12 (POF II, LK 01) Thermohydraulik zur Sicherheitsbewertung
Verlag Karlsruher Institut für Technologie (KIT)
Art der Arbeit Dissertation
Fakultät Fakultät für Maschinenbau (MACH)
Institut Institut für Kern- und Energietechnik (IKET)
Prüfungsdaten 14.12.2012
Schlagwörter Multi-phase, stochastic, critical, CFD, turbulence
Referent/Betreuer Class, A.
KIT – Die Forschungsuniversität in der Helmholtz-Gemeinschaft